UNI-T UT2000 series Manual de instrucciones

Busca en linea o descarga Manual de instrucciones para De medición, control y control UNI-T UT2000 series. UNI-T UT2000 series Instruction manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Page
Attention
International Electrical Symbols
Features
Introduction
Environmental Conditions
Technical Specification
1. Dc Voltage
2. Ac Voltage
3. Dc Current
5. Resistance
6. Capacitance
4. AC Current
7. Temperature
8. Frequency
9. Diode
10 . Transistor hFE
11. Open circuit test
12. Battery test
13. Alarm
14. Square wave output
Safety Rules
Operating Instruction
2
2
2
3
4
5
5
6
7
8
9
10
11
11
12
12
12
12
13
13
13
15
Maintenance
18
Model UT2000: OPERATING MANUAL
1
Table of Contents
Title
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - Table of Contents

PageAttentionInternational Electrical SymbolsFeaturesIntroductionEnvironmental ConditionsTechnical Specification1. Dc Voltage2. Ac Voltage3.

Pagina 2

10 which does not affect the accuracy of the reading. If the resistor under measurement is 100M , The reading will be 101.0, the actu

Pagina 3

117. TemperatureTemperature sensor: International standard K type(NiCr - NiSi) probe.8. FrequencyRESOLUTIONRANGE (1.5%of rdg+15digits) (0.75%of rd

Pagina 4

129. DiodeOverload protection: 250V DC or AC rms.10 . Transistor hFE11. Open circuit testDisplay approx.forward voltageof diodeAllseriesRANGEDESCRIPT

Pagina 5

1313. Alarm200720032002/5200620012004ALARM SOUNDSMis-operationSwitch positionTest leads positionA or 10AA,mA,2A10A10AAOverrangeDisplay >19999*V,

Pagina 6

143. Input Current Jack: There is a 5x20mm fuse inside the “A” input jack. Over range measurement will burn the fuse and replacement

Pagina 7

157. The choice of LCD display angle: see the following diagram.SAFETY RULESThe Digit Multimeter is a precise electronic device.Do not tamper

Pagina 8

5. Do not operate the Meter before the cabinet has been closed and screwed safely as terminal can carry voltage.166. Make sure befor

Pagina 9

1716. Do not operate the Meter under adverse environmental condition including high temperature and especially humid area as the Me

Pagina 10

18Maintenance(1)This section provides basic maintenance informationincluding battery and fuse replacement instruction.WarningDo not attempt to repair

Pagina 11

~ END ~This operating manual is subject to change without notice.194. Remove the battery from the battery compartment.5. Replace the battery wit

Pagina 12 - 12. Battery test

ATTENTIONPlease go through the instruction manual beforeusing your meter and also pay attention to thesection VI. SAFETY RULES.INTRODUCTION£º UT200

Pagina 13

Copyright 2001 Uni-Trend International Limited.All rights reserved.20Manufacturer: UNI-TREND TECHNOLOGY(DONG GUAN)LIMITEDAddress: Dong Fang Da Dao, Be

Pagina 14

FEATURESl DC basic accuracy: (31/2) 0.5%; (4 1/2) 0.05%.l Max. display:1999 (3 1/2 digit) ; 19999 (4 1/2 digit).l Reading displ

Pagina 15

ENVIRONMENTAL CONDITIONSGuarantee accuracy: 23oC 5oC ; relative humidity:<75%.Temperature range: working temperature: 0oC to40oC (32oF to 104oF),s

Pagina 16

TECHNICAL SPECIFICATIONAccuracy: (a% reading + No. of digits), guaranteedfor 1 year.1. DC Voltage4 1/2Digit ACCURACYRESOLUTION (0.5%of rdg+1digit)

Pagina 17

2. AC Voltage6RESOLUTION (0.8%of rdg+3digits)3 1/2 Digit ACCURACYRANGE200mV2V20V200V750V2001 2002/5 2006 2007(1.2%of rdg+3digits)100 V1mV10mV

Pagina 18

73. DC CurrentRESOLUTION (0.8%ofrdg+1digit)3 1/2 DigitACCURACYRANGE200 A2mA20mA200mA2A10A20 A0.1 A1 A10 A100 A1mA10mA10n A200720062002/5

Pagina 19

4. AC CurrentOverload protection: 0.2A/250V fused (Except2001:2A/250V) 10A range isnot fused.Maximum input: 10AFrequency range: 40-400Hz.Indication

Pagina 20

95. ResistanceRESOLUTION3 1/2 Digit ACCURACY2001 2002/5 2006 2007 (0.8%of rdg+1digit)0.11101001K10K (0.8%of rdg+3digits) (1%of rdg+2digits)2002