UNI-T UT206A Especificaciones Pagina 1

Busca en linea o descarga Especificaciones para Multímetros UNI-T UT206A. UNI-T UT206A Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Table of Contents
3
4
5
6
9
10
11
14
17
17
19
20
21
23
25
27
Title Page
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Functional Buttons
Display Symbols
Measurement Operation
A. AC Current Measurement
B. DC Voltage Measurement
C. AC Voltage Measurement
D. Measuring Resistance
E. Testing for Diodes and Continuity
F. Frequency and Duty Cycle (%) Measurement
(Duty Cycle: UT205A only)
G. Temperature Measurement (Model UT206A only)
Model UT205A/206A: OPERATING MANUAL
1
Vista de pagina 0
1 2 3 4 5 6 ... 39 40

Indice de contenidos

Pagina 1

Table of Contents345691011141717192021232527Title PageOverviewUnpacking InspectionSafety InformationRules For Safe OperationInternational Electrical S

Pagina 2

The Meter Structure (see figure 1)(figure 1)1.2.3.4.5.6.Transformer Jaws designed to pick up the AC currentflowing through the conductor.Rotary Switch

Pagina 3 - Overview

Below table indicated for information about the functional button operations.Functional ButtonsOperation PerformedButtonTurn the display backlight on

Pagina 4 - Unpacking Inspection

Operation PerformedButton The Meter is at the DCV – 400mV range or ACV -4V range after returning from the Hz% cycle measurement mode.2.

Pagina 5 - Safety Information

Operation PerformedButtonHOLDPress HOLD to enter and exit the Hold mode in anymode, the Meter beeps.When it is under sleep mode, press to activatethe

Pagina 6 - Rules For Safe Operation

Display Symbols (see figure 2)(figure 2)Model UT205A/206A: OPERATING MANUAL14

Pagina 7

Number Meaning12345ACSymbol%Data hold is active.Indicator for AC Voltage.The battery is low. Warning: To avoid false readings, which could lead to

Pagina 8

Number Meaning89101112SymbolV, mVThe continuity buzzer is on.Test of diodeCentigrade. The unit of temperature.The relative value mode is on to displa

Pagina 9

Measurement Operation(figure 3)A. AC Current Measurement (See figure 3) WarningThe measurement value obtained is wrong if testing two or more current

Pagina 10

1. Set the rotary switch to the current measurement mode.2. Check the lever is in good condition.3. Press the lever to open the transformer jaws.4. Ce

Pagina 11 - Functional Buttons

B. DC Voltage Measurement (See figure 4)(figure 4)WarningTo avoid harms to you or damages to the Meterfrom electric shock, please do not attempt tomea

Pagina 12 - (UT206A only)

282930303031333333343435363636373738Title PageOperation of Hold ModeThe Use of Relative Value Mode(Model UT206A only)The SELECT ButtonTurning on the D

Pagina 13

In each range, the Meter has an input impedance of 10M . This loading effectcan cause measurement errors in high impedance circuits. If the circuit

Pagina 14 - (figure 2)

D. Measuring Resistance (see figure 5)WarningTo avoid damages to the Meter or to the devicesunder test, disconnect circuit power and dischargeall the

Pagina 15

To obtain precision readings in low-resistance measurement, that is the range of400.0 , short-circuit the input terminals beforehand, using the relati

Pagina 16

(figure 6)E. Testing for Diodes and Continuity (See figure 6)To avoid damages to the Meter or to the devicesunder test, disconnect circuit power and d

Pagina 17 - Measurement Operation

3. For continuity test: a. Press SELECT to switch between Diode and Continuity test. b. Connect the test lead to the two end of the circuit u

Pagina 18

(figure 7)F. Frequency and Duty Cycle (%) Measurement (See figure 7)UT205A has both frequency and duty cyclemeasurement feature UT206A has only frequ

Pagina 19 - Red Black

d. Connect the test leads across with the object being measured.The measured frequency value or duty cycle value shows on the display.a. Insert the r

Pagina 20

RedBlackG. Model UT206A: Temperature Measurement (See figure 8)1. Insert the red temperature probe into the oC terminal and the black temperature

Pagina 21

Operation of Hold ModeTo avoid possibility of electric shock, do not use Hold mode to determine ifcircuits are without power. The Hold mode will not

Pagina 22

The REL mode applies to all measurement functions except frequency and dutycycle. It subtracts a stored value from the present measurement value and

Pagina 23 - terminal and the

OverviewThis Operating Manual covers information on safety and cautions. Please read therelevant information carefully and observe all the Warnings an

Pagina 24

The SELECT ButtonIt uses for selecting the required measurement function when there is more thanone function at one position of the rotary switch.Turn

Pagina 25

Maximum Voltage between any Terminals and Grounding: 600V rms or 600V DC. Maximum Current Measurement: 1000A. of Transformer Jaw:

Pagina 26

Battery Type: One piece of 9V (NEDA1604 or 6F22 or 006P). Battery Deficiency: Display Dimensions (HxWxL): 236mm x 97mm x 40mm Weigh

Pagina 27 - C terminal

A. AC CurrentRange Resolution Accuracy Remarks400A1000A0.1A1A(1.5%+5)800A (2%+5)Frequency response 50

Pagina 28

C. AC Voltage40V40V400V600V(1.2%+2)600V DC600V ACRange Resolution AccuracyOverloadProtectionRemarks1mV10mV100mV1V(1.5%+5)Input impedance around 10M

Pagina 29

Range Resolution Accuracy Overload Protection40k400k4M40M101001k10k500V DC or AC(1%+2)(1.2%+2)(1.5%+2)E. Diode an

Pagina 30

F. Frequency (auto-ranging)Range Resolution Accuracy Overload Protection Remarks10Hz-10MHzMin0.001Hz(0.1%+3) 500V DC or VACIn

Pagina 31

MaintenanceThis section provides basic maintenance information including battery replacementinstruction.Do not attempt to repair or service your Meter

Pagina 32

B. Replacing the Battery (See figure 9)Warning(figure 9)To avoid false readings, which could lead topossible electric shock or personal injury,replace

Pagina 33

To replace the battery:1. Turn the rotary switch of the Meter to OFF position and remove all the connections from the terminals.2. Remove the screw

Pagina 34 - AC Voltage

Unpacking InspectionOpen the package case and take out the Meter. Check the following items carefullyto see any missing or damaged part:Item Descript

Pagina 35

Copyright 2006 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Indu

Pagina 36 - 1MHz: 600mV rms a 5V rms

Safety InformationThis Meter complies with the standards IEC61010: in pollution degree 2, overvoltagecategory (CAT. II 600V / CAT III 300V) and double

Pagina 37

Rules For Safe OperationTo avoid possible electric shock or personal injury, and to avoid possible damageto the Meter or to the equipment under test,

Pagina 38

Use the proper terminals, function, and range for your measurements.When using the test leads, keep your fingers behind the finger guards.Disconnect c

Pagina 39

Do not use or store the Meter in an environment of high temperature, humidity,explosive, inflammable and strong magnetic field. The performance of the

Pagina 40

International Electrical SymbolsAC (Alternating Current)DC (Direct Current)AC or DCGroundingDouble InsulatedFuseDeficiency of Built-In BatteryContinui

Comentarios a estos manuales