UNI-T UT56 Manual de usuario Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 2
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
P/N:110401104338X
Range Remark Measuring Condition
hFE
Can Measure NPN
and PNP type
Transistor, Display
ranges: 0-1000 β
Basic polarity current
about 10μA,Vce
about 3.0V
Making Measurements
Caution:
1 On/Off Switch
3 Liquid Crystal Display
5 Rotary switch
7 Input jack
2 Capacitance jack
4 Date Hold Switch
6 Transistor jack
(1) If there is no display or is shown on the
LCD when the Meter is switched on, replace
the battery as soon as possible.
(2) Never exceed the maximum input voltage or
current limits shown besides the input jacks
, otherwise the Meter will be damaged
and this is dangerous to life.
(3) Turn the rotary switch to proper range before
operating.
" "
" "
Measuring DC Voltage
1. Connect the black test lead to COM jack and
red test lead to" V
2. Set the rotary switch to V .
3. Connect the test leads across with the object
to be measured. LCD appears the measured
value and also the polarity of the red test leads.
Caution
1) If magnitude of the voltage is unknown, always
start with the highest range and reduce until
satisfactory reading is obtained.
2) If
1 is shown on the LCD, which means the
Meter is overloaded, then set to a higher
measurement range.
3)
means never exceed the maximum input
limit 1000V, otherwise internal circuit of the
Meter will be damaged.
4) Take extra care of to avoid electric shock when
measuring high voltage.
Measuring AC Voltage
1. Connect the black test lead to COM jack
and red test lead to jack.
2. Set the rotary switch to " ~"
3. Connect the test leads across with the object
to be measured.
Caution
1) Refer to DC Voltage Caution 1, 2, 4.
2)
means never exceed the maximum input
limit 750V, otherwise internal circuit of the
Meter will be damaged.
" "
" jack.
" "
""
" "
" "
" "
" "
" "
V
V
Measuring DC Current
1. Connect the black test lead to COM jack .
When measuring below 200mA, connect the
red test lead to mA jack. When measuring
20A or below, connect the red test lead to
2. Set the rotary switch to A
3. Connect the test leads in series with the object
to be measured, the LCD display the measuring
value and polarity of red test lead.
" "
" "
jack.
" 20A"
" " .
Measuring AC Current
1. Connect the black test lead to " " jack.
When measuring below 200mA, connect the
red test lead to
20A or below, connect the red test lead to
20A jack.
2. Set the rotary switch to" A~
3. Connect the test leads in series with the object
to be measured.
1) Please refer to DC Current Caution 1, 2, 3.
Caution
satisfactory reading is obtained.
2) If 1 is shown on the LCD, which means the
Meter is overloaded, then set to a higher
measurement range.
3)
means the maximum input current is 200
mA, overload will cause the burn of fuse. 20A
range does not have fuse protection
" "
" "
"mA" jack. When measuring
" "
" .
" "
COM
Measuring Resistance
Before measuring capacitance, remember it takes
time for zeroing when changing ranges. Floating
reading do not effect accuracy.
Caution
1) If 1 is shown on the LCD, which means the
Meter is overloaded, then set a higher measuring
range. If resistance is above 1M
Ω, the reading
will only be steady after few seconds which is
normal for measuring high value of resistance.
2) 1 is displayed when no input(e.g. open circuit).
3) Make sure all objects, circuit and components
to be measured are without voltage and
discharge all high-voltage capacitors.
4) At 200M
Ω range, test lead is short circuit, it has
1000 digits which need to be subtracted from
the reading when making measurement. For
example, when measuring 100M
Ω, it displays
110.00, 1000 digits need to be deducted (means
110.00-10.00=100.00M
Ω).
1. Connect the black test lead to COM jack and
red test lead
Ω jack.
2. Set rotary switch to
Ω .
3. Connect the test leads across with the object
to be measured.
1) To avoid damage to the Meter or the equip-
ment under testing, disconnect circuit powers
and discharge capacitors before measuring
capacitance.
2) Connect capacitor to the capacitance jack.
Measuring Capacitance
Caution
" "
" "
" "
" "
" "
3) Stabilizing reading takes some time when
measuring high capacitance.
Unit : 1pF=10
-6
μF, 1nF = 10
-3
μF
Measuring Frequency
When measuring above 30Vrms, accuracy could not
be guaranteed and Take extra care since the voltage
are becoming very dangerous at this moment.
Caution
Measuring Diode and Continuity beeper
1. Set the black test lead to COM jack and red
test lead to V
Ω jack (Red test lead polarity is
"+" ), Set the rotary switch to .
2. Connect the test lead across with the object
being measured.The reading is the approximate
value of forward voltage drop for the diode.
1. Connect red test lead to Hz jack and black
test lead to COM jack.
2. Set the rotary switch to kHz .
3. Connect the test leads across with the object being
measured. LCD appears the frequency value.
" "
" "
" "
" "
" "
Auto-Power Off function
1. Meter equips with auto-power off function. It will
be in a sleep condition when it has worked for 30
minutes. Power will be automatically cut off.
2. Press the on/off switch two times to power
up again.
Maintenance
The Meter is a highly precise electrical testing
instrument, do not attempt to change the circuit
of your Meter on your own. Take a note of the
following few points.
1. Do not connect to DC Voltage above 1000V
or AC RMS above 750V.
2. Do not input voltage when the rotary switch
is in
Ω .
3. Do not operate the Meter if battery is not inside
or bottom cabinet is not securely screwed.
4. Disconnect the test leads and power off the
Meter before replacing the Battery and Fuses.
"Current Range"
"
"
"
"
2. Identify NPN or PNP type, connect objects to
the correspondent transistor jack.
3. LCD appears the hFE nearest value.
4. Measuring condition: Ib 10
μA, Vce 3.0V.
Using Holster
Three different ways to use holster:
1. Set holster parallel on the table, do not open
the tilt stand (see diagram 1)
2. Set holster in a small angle on the table, tilt
it up by the first part of tilt stand (see diagram 2)
3. Set holster in a large angle on the table, tilt it
up by all two parts of tilt stand (see diagram 3).
figure1 figure2 figure3
Using Strap
1. Put the front end of the strap through the round
metal of the Meter, see part 1 of the below
diagram.
2. Put the bottom end of the strap through the front
part and tide it up, see part 2 of the below diagram.
Transistor hFE test
3. Connect the test lead to two ends of the object
being measured, the beeper sounds if the resistant
value between the two ends is below 50
Ω .
Measuring Transistor hFE
1. Set rotary switch to hFE .
Caution
1) If magnitude of the current is unknown, always
start with the highest range and reduce until
Vista de pagina 1