Accuracy Specifications (4)
F. DC Current
Remark:
l 10A Range:
For continuous measurement
10 seconds and
interval time between 2 measurements greater than
15 minutes.
G. AC Current
Remarks:
l Frequency response 40Hz ~ 1kHz.
l Displays effective value of sine wave (mean value
response).
l 10A Range:
For continuous measurement
10 seconds and
interval time between 2 measurements greater than
15 minutes.
Range
340
A
3400
A
34mA
340mA
10A
Resolution
0.1
A
1
A
10
A
100
A
10mA
Accuracy
(1.2%+2)
(1.5%+2)
Overload Protection
0.5A, 250V, fast type
Glass fuse, 5x20 mm.
10A, 250V, fast type
Glass fuse, 5x20 mm.
Range
340
A
3400
A
34mA
340mA
10A
Resolution
0.1
A
1
A
10
A
100
A
10mA
Accuracy
(1.5%+5)
(2.5%+5)
Overload Protection
0.5A, 250V, fast type
Glass fuse, 5x20 mm.
10A, 250V, fast type
Glass fuse, 5x20 mm.