UNI-T UT501 Manual de instalación Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 26
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
LUMA-NET to MICROPLEX
In this application, Microplex or DMX is mixed with LUMA-NET and transmitted as Microplex.
CONNECTOR OPERATION
Microplex IN Input Microplex
Microplex OUT Retransmitting Microplex (64 or 128)
DMX IN Input DMX 512
DMX out Pass through DMX-512
MIDI / Analog Not used
Luma-net Luma-net network
RS-232 Not Used
JUMPER LOCATIONS
P4 & 5 P7 JP6 & 7 JP8 & 9 JP10 JP11 JP12 JP13
CLOSED CLOSED 2-3 N/A 2-3 2-3 1-2 2-3
P6 P8 JP1 DMX OUT CABLE
*CLOSE TO TERM
DMX
CLOSE TO TERM
LUMA
POSITION 2 JP4
DIPSWITCH POSITIONS
C1 C2 C3 C4 ADDRESS 1 - 7 A8
UP UP UP DN STARTING ADDR OF LUMA-NET IN 16 INCREMENT DN:64
Allows 128 channels of Luma-net to be merged with microplex in a ‘‘last action takes precedence’’ fashion.
Terminate DMX or Luma-net by closing jumper P6 or P8 only if last device on line.
*DMX should only be terminated internally if IF501 will be always last unit at end of DMX line. A better way
to terminate is to connect 120ohm resistor to a female DMX cable end (pins 2-3) and plug it into the pass-through
of the last unit on the DMX line.
See operators manual of Luma-net device for additonal information.
Microplex output is sent as either 64 or 128 channels, depending on the setting of switch A8.
INTERFACE UNIT
Software Revision 1.05, Version A LUMA-NET to MICROPLEX
NSI CORPORATION 13